Skip to main content

Login for students

Login for employees

Publication detail

Determination of phenylalanine and tyrosine in plasma and dried blood samples using HPLC with fluorescence detection
Year: 2009
Type of publication: článek v odborném periodiku
Name of source: Journal of Chromatography B
Publisher name: Elsevier Science BV
Place: Amsterdam
Page from-to: 3926-3929
Titles:
Language Name Abstract Keywords
cze Stanovení fenylalaninu a tyrosinu v plazmě a vzorcích suché krve pomocí HPLC s fluorescenční detekcí Byla vyvinuta HPLC metoda pro simultánní stanovení fenylalaninu a tyrosinu ve vzorcích suchých krevních skvrn a plazmě. Pro detekci phenylalaninu a tyrosinu jsme využili jejich vlastní fluorescenci. Pro separaci jsme zvolili kolonu s vázanou reverzní fází LichroCart 125-4, Purospher RP-18e, 5 um. Mobilní fází byla směs ethanolu a deionizované vody (5:95, v/v). Analytické parametry metody byly jak pro fenylalanin, tak také pro tyrosin vyhovující: variační koeficienty pro přesnost v sérii i mezi sériemi byly pod 10%. Výtěžnost metody, určené metodou standardních přídavků, se pohybovala v rozmezí 92,0 a 102,9%. Limit stanovitelnosti byl 10,0 umol/l pro fenylalanin a 5,0 umol/l pro tyrosin. Orientační hodnoty fenylalaninu a tyrosinu u novorozenců se pohybovaly v rozmezí 69,3 +/- 13,1 a 42,7 +/- 12,9 umol/l, u skupiny dobrovolných dárců krve v rozmezí 68,4 +/- 9,9 a 52,1 +/- 10,9 umol/l. suchá krevní skvrna; HPLC; fluorescenční detekce; N-methylfenylalanin; fenylalanin; fenylketonurie; tyrosin
eng Determination of phenylalanine and tyrosine in plasma and dried blood samples using HPLC with fluorescence detection An HPLC method for the simultaneous measurement of phenylalanine and tyrosine in samples of dried blood spots and plasma has been developed and evaluated. We have used an inherent fluorescence of both phenylalanine and tyrosine. For the separation, a reverse-phase column LiChroCart 125-4, Purospher RP-18e, 5 um, was used. The mixture of ethanol and deionized water (5:95, v/v) was used as a mobile phase. Analytical performance of this method is satisfactory for both phenylalanine and tyrosine: the intra-assay and inter-assay coefficients of variation were below 10%. Quantitative recoveries from spiked plasma and blood samples were between 92.0 and 102.9%. The limit of detection was 10.0 and 5.0 umol/L, respectively. The preliminary reference ranges of phenylalanine and tyrosine in a group of newborns are 69.3 +/- 13.1 and 42.7 +/- 12.9 umol/L, in a group of blood donors are 68.4 +/- 9.9 and 52.1 +/- 10.9 umol/L. dried blood spot; HPLC; fluorescence detection; N-methylphenylalanine; phenylalanine; phenylketonuria; tyrosine