Skip to main content

Login for students

Login for employees

Publication detail

Number of Species in Complexation Equilibriua of o-, m- and p-CAPAZOXS with Cd2+, Co2+, Ni2+, Pb2+ and Zn2+ Ions by PCA of UV-VIS Spectra
Year: 2007
Type of publication: článek v odborném periodiku
Name of source: Talanta
Publisher name: Elsevier Science BV
Place: Amsterdam
Page from-to: 115-122
Titles:
Language Name Abstract Keywords
cze Počet částic v komplexotvorných rovnováhách orto-, meta- a para-CAPAZO-XSu s Cd2+, Co2+, Ni2+, Pb2+ a Zn2+ ionty PCA analýzou UV/VIS specter Počet částic v komplexotvorných rovnováhách o-, m- a p-CAPAZOXSu s Cd2+, Co2+, Ni2+, Pb2+ a Zn2+ ionty PCA analýzou UV/VIS spekter. Jde o kritické porovnání vybraných modifikací metody hlavních component při analýze absorbanční matice spekter komplexotvorných rovnovah u o-, m-, p-CAPAZOXSu s vybranými ionty kovů při 25oC. Určení počtu světlo-absorbujících částic v rovnovážné směsi komplexotvorné rovnováhy tvoří důležitou informaci k určení chemického modelu. Vylepšenou identifikaci umožňuje druhá a třetí derivace funkce některých modifikací. Jsou vyčísleny take konstanty stability a rovnovážné koncentrace tvořených komplexů. Mírou spolehlivosti regresního vyhodnocení je především těsnost proložení vypočtených spekter experimentálními daty, a tím také potvrzení navrženého rovnovážného modelu. PCA, Metoda hlavních komponent, FA, Faktorová analýza, Hodnost matice, Počet částic, Počet komponent, Chyba spektrofotometru,
eng Number of Species in Complexation Equilibriua of o-, m- and p-CAPAZOXS with Cd2+, Co2+, Ni2+, Pb2+ and Zn2+ Ions by PCA of UV-VIS Spectra A critical comparison of the selected derivative PCA methods on the absorbance matrix data concerning the complexation equilibria between o-CAPAZOXS and Cd2+, Pb2+ and Zn2+ or m-CAPAZOXS and Cd2+, Co2+, Ni2+ and Zn2+ or p-CAPAZOXS and Cd2+ and Zn2+ at 25oC is provided. As the number of complex species in a complex-forming equilibria mixture is an important step in spectral data treatment, the nine selected index functions for the prediction of the number of light-absorbing species that contribute to a set of spectra is critically tested by the PCA. An improved identification with the second SD(AE) or third derivative TD(AE) and derivative ratio function ROD(AE) for the average error criterion AE is preferred. After the number of various complexes formed the stability constants of species ML, ML2, (and ML3, respectively) type log β11, log β12, (and log β13, respectively) for the system of o-CAPAZOXS (ligand L) with the metals (the standard deviation s(log βpq) of the last valid digits is given in brackets) Cd2+ (6.39(5), 11.51(9)), Pb2+ (4.24(2), 9.01(2)), and Zn2+ (5.18(7), 9.06(10)) and for the system of m-CAPAZOXS with Cd2+ (6.59(20), 11.51(32)), Co2+ (7.19(6), 12.19(8)), Ni2+ (7.64(7), 13.39(12)) and Zn2+ (4.83(3), 9.57(3)) and for the system of p-CAPAZOXS with Cd2+ (6.44(5), 10.99(10), 14.57(25)) and Zn2+ (6.84(16), 13.05(29), 18.74(43)) at 25oC are estimated using SQUAD(84) nonlinear regression of the mole-ratio spectrophotometric data. The computational strategy is presented with goodness-of-fit tests and various regression diagnostics capable of proving the reliability of the chemical model proposed. PCA, Principal component analysis; FA, Factor analysis; Rank of matrix; Number of species; Number of components; Spectrophotometer error;