Skip to main content

Login for students

Login for employees

Publication detail

Characterization of Stationary Phases for Reversed-Phase Chromatography
Authors: Molíková Martina | Jandera Pavel
Year: 2010
Type of publication: článek v odborném periodiku
Name of source: Journal of Separation Science
Publisher name: Wiley-VCH
Place: Weinheim
Page from-to: 453-463
Titles:
Language Name Abstract Keywords
cze Charakterizace stacionárních fází pro chromatografii v systému s obrácenými fázemi Byly srovnávány retenční charakteristiky sedmi chromatografických kolon na bázi silikagelu (Bidentate C18, Silica-hydride, Spherisorb ODS-1, Resolve C18, XTerra C18, XBridge Phenyl a Blaze C8 Polydentate). Kolony se lišily v charakteru nosiče - Silica typ B, hydrosilovaný silikagel a hybridní silikagel se zabudovanými methylovými skupinami nebo ethylenovými můstky - a také v typu chemicky vázané stacionární fáze - C8, C18, fenylové ligandy, endcapované a ne-endcapované s volnými místy, bidentátová a poly-bidentátová s více vazbami na plochu sorbentu. Speciální pozornost byla věnována hydrofobicitě a polarní selektivitě, silanolové aktivitě a „iontové výluce“. Kolony byly porovnávány a klasifikovány na základě výsledků „klasického účinnostního testu“, retence homologické řady n-alkylbenzenů v širokém koncentračním rozsahu vodně-oranické mobilní fáze a naftalensulfonových kyselin ve vodné mobilní fázi bez organického rozpouštědla. Charakterizace kolony; Homologické řady; Lipofilita; Naftalensulfonové kyseliny; Silanolová aktivita
eng Characterization of Stationary Phases for Reversed-Phase Chromatography Retention characteristics of seven silica-based chromatographic columns (Bidentate C18, Silica-hydride, Spherisorb ODS-1, Resolve C18, XTerra C18, XBridge Phenyl and Blaze C8 Polydentate) were compared. The columns differ in the character of the support, including silica type B, hydrosilated silica, and hybrid silica gel with incorporated methyl groups, or ethylene bridges; further in the type of chemically bonded stationary phase, including C18, C8 and phenyl ligands, endcapped and non-endcapped with single point, bidentate and polydentate multi-point attachment to the adsorbent surface. Special attention was focused on hydrophobic and polar selectivity, silanol activity and anionexclusion. The columns were compared and classified on the basis of the results of the classical column performance tests, retention of homologous n-alkylbenzenes over a broad composition range of aqueous-organic mobile phases and of naphthalene sulphonic acids in aqueous mobile phases without organic solvents. Column characterization; Homologous series; Lipophilicity; Naphthalene sulphonic acids; Silanol activity