Skip to main content

Login for students

Login for employees

Publication detail

Comparison of Nonaqueous Hydrophilic Interaction Chromatography with Aqueous Normal-Phase Chromatography on Hydrosilated Silica-Based Stationary Phases
Authors: Soukup Jan | Jandera Pavel
Year: 2013
Type of publication: článek v odborném periodiku
Name of source: Journal of Separation Science
Publisher name: Wiley-VCH
Place: Weinheim
Page from-to: 2753-2759
Titles:
Language Name Abstract Keywords
cze Porovnání nevodné hydrofilní interakční chromatografie s chromatografií s nromálními fázemi s vodně-organickými mobilními fázemi na hydrosilovaných stacionárních fázích Studovali jsme retenční chování fenolických kyselin v nevodných normálních fázích s pufrovanou mobilní fází methanol/acetonitril n hydrosilovaných stacionárních fázích. Silica hydride, Diamond hydride, Bidentate C-18, and cholesterolová kolona vykazují vyšší retenci fenolických kyselin v nevodných mobilních fázích. Byly též zjištěny určité rozdíly v selektivitě mezi nevodnými normálními fázemi a vodnými normálními fázemi, selektivita i rozlišení jsou lepší ve vodných systémech. Retence fenolických kyselin klesé s rostoucí koncentrací methanolu v mobilní fázi. hydrosilovaný silikagel; normální fáze; fenolické kyseliny; teplotní vlivy
eng Comparison of Nonaqueous Hydrophilic Interaction Chromatography with Aqueous Normal-Phase Chromatography on Hydrosilated Silica-Based Stationary Phases We investigated the retention behavior of phenolic acids in nonaqueous normal-phase (NP) LC with buffered methanol/acetonitrile mobile phases on hydrosilated silica-based stationary phases. The silica hydride, Diamond hydride, Bidentate C-18, and Cholesterol columns showed a higher retention of phenolic acids in the nonaqueous mobile phases than in aqueous NP mobile phases. There are some selectivity differences between the aqueous and nonaqueous mobile phases, but generally the resolution and selectivity are better in the aqueous systems. The retention of the phenolic acids tested decreased with increasing concentration of methanol in the mobile phase, up to 20% v/v methanol. At increased temperatures, the retention factors and peak widths decrease in both NP modes, showing linear ln k versus 1/T plots, due to a single retention mechanism over the temperature range from 25 degrees C up to the column stability limit, however, the best separations are achieved at low temperatures. The enthalpic and entropic contributions to the retention were determined, and the differences between the aqueous and nonaqueous modes are possibly due to the adsorbed water layer. hydrosilated silica; normal phase; phenolic acids; temperature effects