Skip to main content

Login for students

Login for employees

Publication detail

Multi-elemental analysis of sulfuric acid by oaTOF-ICP-MS after matrix modification with barium bromide
Authors: Husáková Lenka | Urbanová Iva | Šídová Tereza | Mikysek Tomáš
Year: 2015
Type of publication: článek v odborném periodiku
Name of source: Analytical Methods
Publisher name: Royal Society of Chemistry
Place: Cambridge
Page from-to: 5019-5027
Titles:
Language Name Abstract Keywords
cze Multielementární analýza kyseliny sírové metodou oaTOF-ICP-MS po modifikaci vzorku bromidem barnatým Byla vyvinuta metoda pro simultánní multiprvkovou analýzu kyseliny sírové pomocí hmotnostní spektrometrie s ionizací v indukčně vázaném plazmatu na spektrometru s průletovým analyzátorem s ortogonální akcelerací iontů (oaTOF-ICP-MS). Vzorky byly analyzovány po modifikaci matrice bromidem barnatým. Modifikace vzorku umožnuje separaci síranové matrice ve formě nerozpustného síranu barnatého a zamezuje tvorbě polyatomických iontů síry (SN+, SNH+, SO+, SOH+, SOH2+, SCO+, SNOH+, SO2+, S-2(+), SO2H+, či S2H+), které jsou odpovědné za vznik spektrální interference při stanovení celé řady prvků. Metoda byla použita pro rychlé, správné a přesné stanovení 15 prvků (Be, Ti, V, Cr, Mn, Ni, Co, Cu, Zn, Ga, Ge, As, Sn, Sb, and Te) v ultra-stopové koncentraci. Správnost metody byla ověřena pomocí vysoko rozlišovací hmotnostní spektrometrie s ionizací v indukčně vázaném plazmatu (HR-ICP-MS) jako referenční metody. hmotnostní spektrometrie s ionizací v indukčně vázaném plazmatu; oaTOF-ICP-MS; interference matrice
eng Multi-elemental analysis of sulfuric acid by oaTOF-ICP-MS after matrix modification with barium bromide In this work a novel method for the simultaneous multi-elemental analysis of sulfuric acid by inductively coupled plasma orthogonal acceleration time-of-flight mass spectrometry (oaTOF-ICP-MS) after matrix modification with barium bromide was introduced. For this purpose sample aliquots consisting of 10% (w/ w) sulfuric acid were mixed with barium bromide and after the precipitation of sulfates, the resulting liquid phase was aspirated with a concentric glass nebulizer for TOF-ICP-MS determination. The separation of sulfur as a precipitated non-soluble barium sulfate enables the elimination of spectral interferences originating from different sulfur containing species like SN+, SNH+, SO+, SOH+, SOH2+, SCO+, SNOH+, SO2+, S-2(+), SO2H+, or S2H+ on the determination of e. g. Ti, Zn, Ge, and Cu. After that, direct, reliable, and simultaneous determination of 15 elements (Be, Ti, V, Cr, Mn, Ni, Co, Cu, Zn, Ga, Ge, As, Sn, Sb, and Te) at trace and ultra-trace levels in sulfuric acid were performed under optimum instrumental conditions and by using Rh as an internal standard. Accuracy and precision were assessed by analysing sulfuric acid and by comparison of the results of the proposed method with those obtained by the high resolution ICP-MS method. The results of both methods were in good agreement for Ti, V, Cr, Mn, Ni, Co, Cu, Zn, Ga, Ge, and As. The accuracy for all of the 15 elements was also checked by an analytical recovery study. The reported method has a precision greater than 12.5%. plasma-mass-spectrometry; oa-TOF-ICP-MS; interferences