Přejít k hlavnímu obsahu

Přihlášení pro studenty

Přihlášení pro zaměstnance

Publikace detail

Voltammetric Determination of Linuron Herbi-cide Using a Tricresyl Phosphate-Based Carbon Paste Electrode
Autoři: Ðorđević Jelena | Papp Zsigmond | Guzsvány Valéria | Švancara Ivan | Trtić- Petrović Tatjana | Purenović Milovan | Vytřas Karel
Rok: 2012
Druh publikace: článek v odborném periodiku
Název zdroje: Sensors
Název nakladatele: Molecular Diversity Preservation International
Místo vydání: Basel
Strana od-do: 148-161
Tituly:
Jazyk Název Abstrakt Klíčová slova
cze Voltametrické stanovení Linuronu pomocí uhlíkové pastové elektrody s trikresyl fosfátu. Práce se zabývá stanovením herbicidu Linuronu (3-(3,4-dichlorophenyl)-1-methoxy-1-methylurea) na uhlíkové pastové elektrodě s trikresyl fosfátu.
eng Voltammetric Determination of Linuron Herbi-cide Using a Tricresyl Phosphate-Based Carbon Paste Electrode This paper summarises the results of voltammetric studies on the herbicide 3-(3,4-dichlorophenyl)-1-methoxy-1-methylurea (Linuron), using a carbon paste electrode containing tricresyl phosphate (TCP-CPE) as liquid binder. The principal experimental conditions, such as the pH effect, investigated in Britton-Robinson buffer solutions (pH 2.0–7.0), the peak characteristics for the analyte of interest, or instrumental parameters for the differential pulse voltammetric mode were optimized for the method. As found out, the best electroanalytical performance of the TCP-CPE was achieved at pH 2.0, whereby the oxidation peak of Linuron appeared at ca. +1.3 V vs. SCE. The analytical procedure developed offers good linearity in the concentration range of 1.25–44.20 μg mL−1 (1.77 × 10−4–5.05 × 10−6 mol L−1), showing --- for the first time --- the applicability of the TCP-CPE for anodic oxidations in direct voltammetry (without accumulation). The method was then verified by determining Linuron in a spiked river water sample and a commercial formulation and the results obtained agreed well with those obtained by the reference HPLC/UV determination. Linuron; Tricresyl Phosphate; Carbon paste electrode