Measuring of the BLEVE Internal Processes
Autoři: Švihovský Jaroslav | Janovský Břetislav | Skácel Radovan
Rok: 2003
Druh publikace: článek ve sborníku
Název zdroje: Proceedings of the6th International Seminar ?New Trends in Research of Energetic Materials?
Název nakladatele: KTTV, Univerzita Pardubice
Místo vydání: Pardubice
Strana od-do: 405-410
Tituly:
Jazyk Název Abstrakt Klíčová slova
cze depressurization, metastable state, blast wave propagation, BLEVE
eng Measuring of the BLEVE Internal Processes In the present context, the term BLEVE is used for a sudden release of liquid with temperature higher than its boiling point from the container at the failure time, with a total collapse of the container. Most theories about the formation of BLEVE are based on evaporation dynamics and pressure changes inside the container. In the available theories, however, there is a gap in clarifying the initiatory process mechanism, which is going on during and immediately after the collapse of the container. The upcoming experimental works are conducted with the intention to unify the notions of this initiatory process. In the text of this contribution are described apparatuses, which were used during researches on BLEVE problems and which became a basis for the proposed apparatus. The proposed apparatus, together with the matrix of the experiment, is mentioned at the end of this contribution. depressurization, metastable state, blast wave propagation, BLEVE